<LOGO>
FM Transmitter Measurement Report
Created: 2025-08-18 08-56-24
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 3/5, 53 dBuV SANDELS
Pilot RDS Phase Difference
6.1 kHz 5.1 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
13 kHz 18 kHz 7189 0,1113
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
3,6 dBr 4,52 dBr 5,6 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
92.0, 94.7, 106.4, 107.5 MHz -
FM Scope Max at: 18 kHz MIN: 13 kHz % above 76 kHz: 0,1113 Acquired: 2025/08/18 8.55.20 Total samples: 7189 Equivalent time: 0:05:59 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200 300 400
FM Scope MAX: 5,6 dBr MIN: 3,6 dBr AVE: 4,52 dBr % above 12,2 dBr: 0,0 Last value: 4,3 dBr (2025/08/18 8.55.20) 08.42 08.44 08.46 08.48 08.50 08.52 08.54 0 2 4 6 Pm [dBr]